Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 26 of 26 items found.

  • Fibre Optic Video Link

    V-250 - Scitec Instruments Ltd

    Fibre optic video links offer immunity to the effects of radiated interference, high voltage differentials, water, ground loops and the effects of hazardous environments. The systems offered here are fully compatible with B&W or colour NTSC, SECAM, PAL and D2MAC video standards.

  • Stripline Automotive 10KHz-30MHz 50 Ohm

    STPL-30 - EMCTEST

    The GTEMCELL STPL-30 Stripline is designed to produce high electric fields over a controlled bandwidth. It is used to perform EMC measurements according to automotive and aerospace standards in order totest the immunity of automotive and aircraft equipment to radiated electromagnetic fields.The STPL-30 uses a dual-sided tapered adjustable feed design into a tunable transmission line.

  • RF Amplifiers up to 1000 MHz

    Empower RF Systems, Inc.

    Narrow and Broad band high power RF modules and rack mount amplifier systems using solid state devices including LDMOS and GaAs in Class A and Class A/B topologies for Pulse, AM, FM, continuous wave and digital modulation applications that include EW, Radar, Jamming, EMI and EMC radiated immunity, and wireless communications testing.

  • TEM Cells

    EMCTEST

    Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.

  • E-Series Average Power Sensor

    E9304A - Keysight Technologies

    Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • Antenna, Octave Band Horn

    EM-7021 | 2 GHz – 5 GHz - Electro-Metrics Corp.

    Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.

  • Antenna, Octave Band Horn

    EM-7020 | 1 GHz – 2.5 GHz - Electro-Metrics Corp.

    Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.

  • Antenna, Octave Band Horn

    EM-7022 | 4 GHz – 10 GHz - Electro-Metrics Corp.

    Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.

  • ESD Protection

    STMicroelectronics

    Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.

  • LETIS

    Laplace Instruments Ltd.

    Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.

  • EMC Testing

    Keystone Compliance

    Keystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing. EMC TestingKeystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing.Our EMC/EMI testing capabilities include but are not limited to:Radiated immunity testing up to 200 V/m from 10 kHz to 40 GHzRadiated emissions testing up to 40 GHzSurge testing to 10kV/10kA – and higherElectrostatic Discharge “ESD” testing up to 30 kVConducted immunity testing to levels well above the highest defined “standard” levelsMagnetic field immunity testing up to 100 A/m continuous and 1000 A/m short/impulseCustomized transient waveforms to extend level, duration and/or repetition of the standard’s definitionShielding Effectiveness from small panels and boxes all the way up to large enclosures and cabling, with a wide dynamic range all the way to 40 GHzWhat differentiates Keystone Compliance from other EMI test labs is our consultative engineering and expedited EMI test reports. Our staff understand EMC/EMI testing and has extensive experience with radiated immunity, radiated emissions, conducted immunity, conducted emissions, surge, ESD and shielding effectiveness testing. We also cater to specialized testing requirements. If you do not see the test standard or testing requirement you are looking for, please contact us as we may still be able to assist you.For more information about our scope of accreditation, please visit the links below.CISPR StandardsIEC/EN Product Family StandardsIEC/EN Test StandardsISO, SAE and Vehicle StandardsMilitary StandardsFCC, North American and International StandardsShielding Effectiveness TestingLightning and Surge Testing